BUY NOW, PAY LATER WITH AFFIRM - INTEREST FREE CREDIT AVAILABLE IN CART - LEARN MORE

Senville AURA 48,000 BTU Multi-Zone Mini-Split Heat Pump, 6 Zones – SENA/48HF/S

From $6,430.99

-

  • Heats down to -30 °C · cools · dehumidifies
  • 6 indoor units, one outdoor unit
  • SEER2 23 · R-454B refrigerant
  • 10-year compressor, 5-year parts warranty
  • May qualify for rebates when installed by a licensed contractor

Description

The Senville AURA 48,000 BTU multi-zone mini-split heat pump, 6 zones (SENA/48HF/S) heats, cools and dehumidifies six rooms from a single outdoor unit, each with its own temperature. Its inverter compressor adjusts output continuously for steady comfort and lower energy use, and it keeps heating down to -30 °C outside.

Which room is it for?

This 48,000 BTU outdoor unit runs 6 indoor units, one per room. Available combinations: 6,000 + 6,000 + 6,000 + 6,000 + 6,000 + 6,000 BTU; 6,000 + 6,000 + 6,000 + 6,000 + 6,000 + 9,000 BTU; 6,000 + 6,000 + 6,000 + 6,000 + 6,000 + 12,000 BTU; 6,000 + 6,000 + 6,000 + 6,000 + 6,000 + 18,000 BTU; 6,000 + 6,000 + 6,000 + 6,000 + 6,000 + 24,000 BTU; 9,000 + 9,000 + 9,000 + 9,000 + 9,000 + 9,000 BTU; 9,000 + 9,000 + 9,000 + 9,000 + 9,000 + 12,000 BTU; 9,000 + 9,000 + 9,000 + 9,000 + 9,000 + 18,000 BTU; 9,000 + 9,000 + 9,000 + 9,000 + 9,000 + 24,000 BTU; 12,000 + 12,000 + 12,000 + 12,000 + 12,000 + 12,000 BTU. Size each indoor unit to its room: 6,000 BTU for a small bedroom, 9,000 BTU for a bedroom, 12,000 BTU for a living room, 18,000 BTU or more for an open-concept area.

Key features

  • Heats down to -30 °C outdoors (cold-climate heat pump)
  • Cooling, heating, dehumidifying and fan modes in one system
  • High efficiency: SEER2 23, HSPF2 11
  • ENERGY STAR certified
  • R-454B refrigerant, the new lower-impact generation
  • Remote control, Wi-Fi app and Alexa compatible
  • Self-diagnosis and refrigerant leak detection
  • Senville warranty: 10 years on the compressor and 5 years on parts (professional installation required)
  • Power supply: 208/230 V

What’s in the box

  • Inverter outdoor unit
  • Indoor units in the combination you choose
  • Remote control and Wi-Fi / Alexa kit
  • 16 ft installation kits (one per zone), with optional upgrades
  • Connection cable and manuals

Electrical and installation

Plan a dedicated 208/230 V circuit with a minimum circuit ampacity of 43 A and a maximum fuse of 45 A. The outdoor unit is pre-charged with refrigerant for 150 ft of line set in total; longer runs need extra refrigerant added by the installer. Have the electrical connection done by an electrician.

Installation and rebates

This heat pump must be installed and commissioned by a qualified professional (licensed contractor and certified refrigeration technician). This is a condition of the Senville warranty and of most rebate programs.

In Quebec, an ENERGY STAR certified heat pump bought from a Quebec-based business such as Thermomurale and installed by a licensed contractor may qualify for Hydro-Québec’s LogisVert rebate. Outside Quebec, check your provincial program. See our Heat Pump Rebates page or call us at 819-996-7253 and we will help you pick the right model. Thermomurale sells equipment only: installation is done by the licensed contractor of your choice.

Shipping and payment

We ship across Canada, free on orders of $500 or more. Pay over time with Affirm.

SENA/48HF/S: frequently asked questions

How much space can it heat?
Size each indoor unit to its own room; the outdoor unit’s total capacity is shared between zones. Call us to confirm your combination.

Will it heat through a Canadian winter?
Yes, it heats down to -30 °C outside. Output drops in extreme cold, so keep your baseboards or a backup heat source for the coldest days.

What electrical supply does it need?
A 208/230 V circuit with a minimum circuit ampacity of 43 A and a 45 A maximum fuse.

Technical specifications

Senville model number SENA-48HF-MOA
Type Multi-Zone Mini-Split Heat Pump, 6 Zones
Number of zones 2-6
Power supply (V-Ph-Hz) 208/230 V, 1 ph, 60 Hz
Voltage range (V) 187-253
SEER2 23
EER2 12
Cooling capacity (BTU/h) 47000
Cooling range (BTU/h) 12000~57000
Power input, cooling (W) 800~5400
Current, cooling (A) 7~24
Heating capacity (BTU/h) 49000
Heating range (BTU/h) 13000~57000
Power input, heating (W) 800~5200
Current, heating (A) 7~23
HSPF2 (region 4) 11
HSPF2 (region 5) 9
COP (W/W) 3.7
Minimum circuit ampacity (A) 43
Maximum fuse (A) 45
Outdoor airflow, max. (CFM) 4502.8
Outdoor sound level (dB) 65
Outdoor unit size (W x D x H, in.) 37.48 x 16.34 x 52.48
Outdoor unit weight 246.47 lb
Minimum outdoor temperature, heating -30 °C (-22 °F)
Refrigerant / charge (oz) R454B / 151.68
Refrigerant pre-charge 150 ft
Warranty 10 years compressor / 5 years parts

Source: Senville spec sheet, November 2026. Specifications may change without notice.

Compare with the other models in this range: comparison spec sheet.

Video

Senville - Mini Climatiseur Split (Visite guidée)
WiFi activé Smart Mini de Split Climatiseurs

Reviews

There are no reviews yet.

Be the first to review “Senville AURA 48,000 BTU Multi-Zone Mini-Split Heat Pump, 6 Zones – SENA/48HF/S”